header_dachventilatoren.jpg

Roof Fans

EC Roof fans (Type: DV/S...G / DVE/S...G / DVW/S...G)

Properties

  • flow rates up to 15,000 m³/h
  • size: 190 - 710 mm (impeller diameter)
  • vertical outlet
  • highly efficient EC technology
  • backward curved impellers
  • mounted on/off switch
  • solid weatherproof casing
  • easy to install
  • integrated control system (EC controller)
  • speed is 100% infinitely variable
  • integrated pressure sensor (type: pressure control)

» Design and Downloads

Casing

Base frames with threaded bolts for tightening of suction side accessories and retracted inlet cone made of galvanised sheet metal steel. Rain protective hood and square casing made of seawater-proof aluminium. Motor cage with integrated contact-protection made of plastic coated round bar steel. Housing with integrated sound insulation (S) for design DV(S)...G, DVE(S)...G and DVW(S)...G.

Impellers

Impellers are mounted directly to the rotor of the external rotor EC motor and are dynamically balanced on two levels with the rotor according to quality level G 2,5 / G 6,3 as per DIN ISO 21940-11.

model - DV(S)...G
Backward curved impellers made of plastic.
model - DVE(S)...G
Efficiency optimized and sound optimized backward curved impellers of the REVOLUTION series made of plastic.
model - DVW(S)...G
Efficiency optimized backward curved impellers made of aluminum.

Electrical connection

up to size 225
The motors are equipped with a built-on terminal box with easy access for electrical connection after removal of the rain cover.
from size 250
The electrical connection is possible over the mounted ON/OFF-switch.
Type "open loop"
In the “open loop” (standard) model, the speed is continuously provided by a 0-10V signal or a potentiometer (accessories).
Type "closed loop"
In the “closed loop” model, the pressure setpoint is continuously provided via a pre-wired potentiometer or a 0-10V signal. The pre-assembled pressure sensor has a display (Sizes 190-310 without display) with an adjustable pressure measurement range of (100 Pa, 300 Pa, 500 Pa, 1000 Pa).

Downloads

Catalogue: WORLD OF EC FANS Catalogue: WORLD OF EC FANS

Dateiformat: .pdf

Dateigröße: 24.35 MB

Operating manual: Fans with EC-drives (BA044) Operating manual: Fans with EC-drives (BA044)

Dateiformat: .pdf

Dateigröße: 2.50 MB

Construction scheme: EC Roof fans Construction scheme: EC Roof fans

Dateiformat: .pdf

Dateigröße: 632.45 kB


Roof fans (Type: DV/S, DVE/S)

Properties

  • flow rates up to 17,000 m³/h
  • size: 190 - 800 mm (impeller diameter)
  • vertical outlet
  • backward curved impellers
  • different models
  • solid weatherproof casing
  • easy to install

» Design and Downloads

Casing

The casing of the Rosenberg roof fans DV(S) and DVE(S) consists of seawater-resistant aluminium and a base frame with integrated inlet cone (from size 560 with additional plastic coating). Casing with integrated sound insulation (Type DVS and DVES)

Impellers

Impellers are mounted directly to the rotor of the external rotor EC motor and are dynamically balanced on two levels with the rotor according to quality level G 2,5 / G 6,3 as per DIN ISO 21940-11.

model - DV(S)
Backward curved impellers made of plastic.
model - DVE(S)
Efficiency optimized and sound optimized backward curved impellers of the REVOLUTION series made of plastic.

Electrical connection

The drive motors are fitted with a set-up terminal box in IP54, which is easily accessible for the electrical connection after removing the rain guard. Upon request, the device switch can be mounted (optional) on the casing of the fan.

Downloads

Catalogue: WORLD OF AC FANS Catalogue: WORLD OF AC FANS

Dateiformat: .pdf

Dateigröße: 37.52 MB

Operating manual: Fans with AC-drives (BA045) Operating manual: Fans with AC-drives (BA045)

Dateiformat: .pdf

Dateigröße: 1.50 MB

Construction scheme: Roof fans Construction scheme: Roof fans

Dateiformat: .pdf

Dateigröße: 383.57 kB


Roof fans (Type: DH, DHE)

Properties

  • flow rates up to 15,000 m³/h
  • size: 190 - 630 mm (impeller diameter)
  • horizontal outlet
  • backward curved impellers
  • solid weatherproof casing
  • easy to install

» Design and Downloads

Casing

The casing of the Rosenberg roof fans (DH, DHE) consists of seawater-resistant aluminium and a base frame with integrated inlet cone.

model - DH
Hood made of seawater-resistant aluminium; base frame with integrated inlet cone made of galvanised steel sheet
model - DHE
up to size 500: Hood made of seawater-resistant aluminium; base frame with integrated inlet cone made of galvanised steel sheet
from size 560: Hood made of galvanised steel; base frame with integrated inlet cone made of galvanised steel sheet and additionally plastic coated

Impellers

Impellers are mounted directly to the rotor of the external rotor EC motor and are dynamically balanced on two levels with the rotor according to quality level G 2,5 / G 6,3 as per DIN ISO 21940-11.

model - DH
Backward curved impellers made of plastic.
model - DHE
Efficiency optimized and sound optimized backward curved impellers of the REVOLUTION series made of plastic.

Electrical connection

The drive motors are fitted with a set-up terminal box in IP54, which is easily accessible for the electrical connection after removing the rain guard. Upon request, the device switch can be mounted (optional) on the casing of the fan.

Downloads

Catalogue: WORLD OF AC FANS Catalogue: WORLD OF AC FANS

Dateiformat: .pdf

Dateigröße: 37.52 MB

Operating manual: Fans with AC-drives (BA045) Operating manual: Fans with AC-drives (BA045)

Dateiformat: .pdf

Dateigröße: 1.50 MB

Construction scheme: Roof fans Construction scheme: Roof fans

Dateiformat: .pdf

Dateigröße: 383.57 kB


Roof fans with IEC standard motor (Type: DVNF/S, DVN/S)

Properties

  • flow rates up to 36,000 m³/h
  • size: 310 - 900 mm (impeller diameter)
  • vertical outlet
  • IEC standard motors as drive
  • suitable for higher conveying temperatures
  • backward curved impellers
  • different models
  • solid weatherproof casing
  • easy to install
  • DVNF with integrated frequency converter

» Design and Downloads

Casing

The casing of the Rosenberg roof fans (DVNF/S, DVN/S) consists of seawater-resistant aluminium and a base frame with integrated inlet cone.

model - DVNF/DVN
up to size 500: Base frame with integrated inlet cone made of galvanised sheet steel
from size 560: Base frame with integrated inlet cone made of galvanised sheet steel and additional plastic coating
model - DVNFS/DVNS
Casing with integrated sound insulation (S) ; base frame with integrated inlet cone made of galvanised sheet steel and additional plastic coating
up to size 500: Base frame with integrated inlet cone made of galvanised sheet steel
from size 560: Base frame with integrated inlet cone made of galvanised sheet steel and additional plastic coating

Impellers

Efficiency-optimised high performance impellers with backward curved blades made of aluminium. The impellers together with the impeller hub are dynamically balanced on two levels with the rotor according to quality level G 2,5 / G 6,3 as per DIN ISO 21940-11. The impellers are mounted overhung on the shaft of an IEC standard motor type B5.

Electrical connection

model - DVNF/DVNFS
The electrical connection is mounted on the housing by a frequency converter. With model -GS the electrical connection mounted directly by the ON/Off-switch.
model - DVN/DVNS
The wiring box of the motor is easily accessible. The motor has to be connected according to the wiring diagram and in accordance with valid regulations and local laws. With model -GS the electrical connection mounted directly by the ON/Off-switch.

Downloads

Catalogue: Roof Fans with IEC Standard Motor Catalogue: Roof Fans with IEC Standard Motor

Dateiformat: .pdf

Dateigröße: 8.43 MB

Operating manual: Fans with IEC standard motor (BA009) Operating manual: Fans with IEC standard motor (BA009)

Dateiformat: .pdf

Dateigröße: 1.86 MB

Construction scheme: Roof fans Construction scheme: Roof fans

Dateiformat: .pdf

Dateigröße: 383.57 kB

We use cookies

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.