header_kuechenabluft.jpg

Kitchen Exhaust Fans

Kitchen exhaust unit (Type: KBA...)

Properties

  • flow rates up to 8,200 m³/h
  • size: 180 - 500 mm (impeller diameter)
  • motor out of air stream
  • conveying liquid temperatures up to 100°C possible
  • for the exhaust of dirty and greasy air
  • efficiency-optimised casing-impeller combination
  • high efficiency
  • door hinge DIN right/left can be variably converted

» Design and Downloads

Casing

The casing consists of a double-skinned galvanised sheet steel with a non-flammable rock wool acoustic and moisture insulation. The motor-impeller unit can be pivoted for cleaning purposes by the generous operating door. The door hinge DIN right can be easily be converted to DIN left. Connecting pieces fit standard pipes.

Impellers

up to size 280
forward curved impeller made of galvanised sheet steel
from size 315
backward curved impellers made of aluminium
The impellers and the hubs as a unit are dynamically balanced on two levels with the rotor according to quality level G 2,5 / G 6,3 as per DIN ISO 21940-11.

Electrical connection

The electrical connection is on the terminal box already loosely pre-assembled on the cable. The nominal voltage is indicated on the type shield and will allow for a voltage tolerance of ±10%.

Downloads

Catalogue: WORLD OF AC FANS Catalogue: WORLD OF AC FANS

Dateiformat: .pdf

Dateigröße: 37.52 MB

Operating manual: Fans with AC-drives (BA045) Operating manual: Fans with AC-drives (BA045)

Dateiformat: .pdf

Dateigröße: 1.50 MB

Construction scheme: Kitchen exhaust unit Construction scheme: Kitchen exhaust unit

Dateiformat: .pdf

Dateigröße: 404.23 kB


EC-Unobox-ME (Type: EC-UNO-ME)

Properties

  • flow rates up to 13,000 m³/h
  • size: 355 - 630 mm (impeller diameter)
  • motor out of air stream
  • high conveying media temperatures possible
  • backward curved impellers
  • integrated control system (EC controller)
  • discharge upward (standard), operating side can be exchanged
  • with built-in emergency stop

» Design and Downloads

Casing

The flexible and compact EC Unoboxes ME are designed to handle air volumes with higher temperatures. A removable service door, an integrated drip pan with condensation drain nozzle, plus special sealing lips are included. The housing supporting frames are double chamber aluminum profiles with corners made of plastic and double skinned (20 mm) galvanized sheet steel panels insulated with non-inflammable, noise and temperature insulating fibreglass mats. Optionally, the outlet side (at the top or the side) can be selected. A changing of the air outlet and side panel at the installation site is possible at any time by setting of the flexible panels.

Impellers

Backward curved high-performance impellers made of aluminium are used. The impellers together with the impeller hub are dynamically balanced on two levels with the rotor according to quality level G 2,5 / G 6,3 as per DIN ISO 21940-11.

Electrical connection

The integrated motor protection is signaled via alarm relay. The electrical connection takes place on the preassembled isolator switch in the housing. In the version „open-loop control“(standard) the speed is adjusted via 0-10V Signal or a potentiometer (accessory). The connection hereto takes place directly at the EC-Controller inside the EC Unobox ME.

Downloads

Catalogue: WORLD OF EC FANS Catalogue: WORLD OF EC FANS

Dateiformat: .pdf

Dateigröße: 24.44 MB

Operating manual: Box Fans with EC drives (BA056) Operating manual: Box Fans with EC drives (BA056)

Dateiformat: .pdf

Dateigröße: 3.25 MB

Construction scheme: EC Unobox ME Construction scheme: EC Unobox ME

Dateiformat: .pdf

Dateigröße: 445.07 kB


Unobox-ME (Type: UNO-ME)

Properties

  • flow rates up to 20,000 m³/h
  • size: 355 - 630 mm (impeller diameter)
  • motor out of air stream
  • high conveying media temperatures possible
  • backward curved impellers
  • removable control cover for easy cleaning
  • discharge upward (standard), operating side can be exchanged
  • with built-in emergency stop

» Design and Downloads

Casing

The Rosenberg Unoboxes ME are designed to handle volume flows with low to medium conveying media temperatures. The housing consists of a frame made of an extruded aluminium profile with 2 chambers and plastic edges, as well as double-skinned, 20mm thick panels made of galvanised steel sheet metal with insulation made of non-combustible, sound and heat-insulated glass wool mats. The discharge and the operator side are interchangeable.

Impellers

Backward curved impellers made of high-performance aluminium are used. The impellers together with the impeller hub are dynamically balanced on two levels with the rotor according to quality level G 2,5 / G 6,3 as per DIN ISO 21940-11.

Electrical connection

Connection will be done on the frontal mounted emergency switch.

Direction of rotation

The direction of rotation of the impellers is standard clockwise rotation (seen from the suction side). Counter-clockwise operation will cause overload damage to the motor.

Downloads

Catalogue: WORLD OF AC FANS Catalogue: WORLD OF AC FANS

Dateiformat: .pdf

Dateigröße: 37.52 MB

Operating manual: Fans with AC-drives (BA045) Operating manual: Fans with AC-drives (BA045)

Dateiformat: .pdf

Dateigröße: 1.50 MB

Construction scheme: Unobox ME Construction scheme: Unobox ME

Dateiformat: .pdf

Dateigröße: 478.07 kB


Roof fans with IEC standard motor (Type: DVNF/S, DVN/S)

Properties

  • flow rates up to 36,000 m³/h
  • size: 310 - 900 mm (impeller diameter)
  • vertical outlet
  • IEC standard motors as drive
  • suitable for higher conveying temperatures
  • backward curved impellers
  • different models
  • solid weatherproof casing
  • easy to install
  • DVNF with integrated frequency converter

» Design and Downloads

Casing

The casing of the Rosenberg roof fans (DVNF/S, DVN/S) consists of seawater-resistant aluminium and a base frame with integrated inlet cone.

model - DVNF/DVN
up to size 500: Base frame with integrated inlet cone made of galvanised sheet steel
from size 560: Base frame with integrated inlet cone made of galvanised sheet steel and additional plastic coating
model - DVNFS/DVNS
Casing with integrated sound insulation (S) ; base frame with integrated inlet cone made of galvanised sheet steel and additional plastic coating
up to size 500: Base frame with integrated inlet cone made of galvanised sheet steel
from size 560: Base frame with integrated inlet cone made of galvanised sheet steel and additional plastic coating

Impellers

Efficiency-optimised high performance impellers with backward curved blades made of aluminium. The impellers together with the impeller hub are dynamically balanced on two levels with the rotor according to quality level G 2,5 / G 6,3 as per DIN ISO 21940-11. The impellers are mounted overhung on the shaft of an IEC standard motor type B5.

Electrical connection

model - DVNF/DVNFS
The electrical connection is mounted on the housing by a frequency converter. With model -GS the electrical connection mounted directly by the ON/Off-switch.
model - DVN/DVNS
The wiring box of the motor is easily accessible. The motor has to be connected according to the wiring diagram and in accordance with valid regulations and local laws. With model -GS the electrical connection mounted directly by the ON/Off-switch.

Downloads

Product information: DVNF Product information: DVNF

Dateiformat: .pdf

Dateigröße: 971.50 kB

Operating manual: Fans with IEC standard motor (BA009) Operating manual: Fans with IEC standard motor (BA009)

Dateiformat: .pdf

Dateigröße: 1.86 MB

Construction scheme: Roof fans Construction scheme: Roof fans

Dateiformat: .pdf

Dateigröße: 383.57 kB

 

We use cookies

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.